X-10 Analyzer
The X-10 Analyzer counts the number of carrier cycles in the X-10 receive window (between ZC+250µS and ZC+900µS) and measures the 120kHz carrier amplitude at ZC+575µS. It outputs the digital data via an optoisolated RS232 link (19200 8N1). The analyzer can also inject X-10 PLC signals to the powerline. Windows, Linux (and soon OS X) applications interface with the RS-232 output, writing the data to a file and providing tools for display and analysis.
NOTE: The 6P6C pinout allows for use of the same DB9F-6P6C adapter as is used with S1,S2,S3.
CAUTION: The CH1 & CH2 oscilloscope test points require that the oscilloscope be isolated from the mains.